Skip to main content

Table 5 Comparison of changes in stratum corneum hydration (n = 88)

From: Venous dilation effect of hot towel (moist and dry heat) versus hot pack for peripheral intravenous catheterization: a quasi-experimental study

SCH (A.U.)

Change in heating = T2 – T1

(After heating – Baseline)

Change after removed = T3 – T2

(After tourniquet – After heating)

Hot pack

Mean (SD)

12.2 (8.4)

-5.3 (6.4)

Dry hot towel

10.2 (8.3)

-5.1 (6.0)

Moist hot towel

35.1 (18.8)

-28.4 (14.8)

Hot pack vs. Dry hot towel

MD [95%CI]

2.00 [-2.48–6.59]

0.19 [-3.45–3.83]

t, d

1.00, 0.24

0.12, 0.05

Pa

.319

.907

Hot pack vs. Moist hot towel

MD [95%CI]

22.87 [18.91–26.84]

23.30 [19.69–26.92]

t, d

11.39, 1.42

14.24, 1.81

Pa

 < .001

 < .001

Dry hot towel vs. Moist hot towel

MD [95%CI]

24.88 [20.43–29.33]

23.30 [20.11–26.50]

t, d

12.48, 1.56

14.41, 1.83

Pa

 < .001

 < .001

  1. A.U. arbitrary units, CI conference interval, MD mean difference, SCH stratum corneum hydration, SD standard deviation
  2. aA mixed-linear model for one-way repeated-measures ANOVA and Bonferroni correction (P < .0167)